Fender Style Transformer wiring diagrams and spec's.
|
Fender Style Output Transformer spec's.
|
|
PART# |
MOUNTING |
HEIGHT |
LENGTH |
WIDTH |
WATTS |
PRIMARY |
SEC |
LBS. |
|
022921 |
1 3/4" Approx |
1 3/4" |
1 3/8" |
1 3/8" |
3.5 |
14,500 |
4 |
6.5 OZ |
|
022905 |
2 3/8" |
1 5/8" |
1 7/8" |
1 7/8" |
8 |
7000 |
4 |
12 OZ |
|
022913 |
2 13/16" |
2" |
2 5/16" |
2" |
12 |
8500 |
8 |
15 OZ |
|
041318 |
3 1/8" |
2 1/4" |
2 3/4" |
2 1/4" |
25 |
8500 |
8 |
1.5 LB |
|
022848 |
3 9/16" |
2 5/8" |
3 1/8" |
2 5/8" |
50 |
4000 |
4 |
2.3 LB |
|
018343 |
2 X 3 7/16" |
3 1/2" |
3 3/4" |
3" |
50 |
4000 |
2,4,8 |
4.5 LB |
|
022855 |
2 1/4 X 3 1/4" |
3 1/4" |
3 3/4" |
3 3/8" |
50 |
4000 |
2 |
4.4 LB |
|
022899 |
2 1/4 X 3 1/2" |
3 1/4" |
3 3/4" |
3 1/4" |
100 |
2000 |
4 |
5.3 LB |
Fender Style Chokes
|
|
PART# |
MOUNTING |
HEIGHT |
LENGTH |
WIDTH |
LBS. |
|
125C3A |
2" |
1 3/8" |
1 11/16" |
1 3/8" |
6 OZ |
|
125C1A |
2 13/16" |
2" |
2 5/16" |
1 3/4" |
15 OZ |
Note: If your
power transformer has a center tap for the green heater wires and you
replace it with a non center tapped power transformer, you will have to add
two 1/2 watt 100 ohm resistors to the heater circuit to make an artificial
center tap.
This page will explain how to do that.
http://www.el34world.com/fenderservice4.htm
Note: To determine if you have Version A or Version B TBPT,
use a multi meter set to continuity.
You will get a beep from the Orange wire to the Brown or Black wires on Version A.
You will get a beep from the Orange wire to the Brown/White or Black/White wires on Version B.
TBPT Version A primary hookup
Line = The AC connection. Blk=Black, Brn=Brown, Wht=White |
| 120 vac |
Line - |
Twist together Brown and Brown/White |
| . |
Line - |
Twist together Black and Black/White |
| . |
. |
Do not use Orange. Heat shrink the tip. |
| - |
| 240 vac |
Line - |
Brown |
| . |
Line - |
Black/White |
| . |
. |
Twist together Black and Brown/White |
| . |
. |
Do not use Orange. Heat shrink the tip |
| - |
| 220 vac |
Line - |
Orange |
| . |
Line - |
Black/White |
| . |
. |
Twist together Black and Brown/White |
| . |
. |
Do not use Brown. Heat shrink the tip |
| - |
| 100 vac |
Line - |
Orange |
| . |
Line - |
Black |
| . |
. |
Do not use Brown. Heat shrink the tip |
| . |
. |
Do not use Brown/White. Heat shrink the tip |
| . |
. |
Do not use Black/White. Heat shrink the tip |
Note: The last batch of TBPT's that I received from Victoria
amps has the orange wire moved to the other primary. I think the transformer guy just got the two primaries mixed up
but it will not matter since both primaries are equal. I made a new diagram above and instructions below for wiring
this Version B model as I am calling it. Nothing is different except that the orange wire has been moved.
TBPT Version B primary hookup
Line = The AC connection. Blk=Black, Brn=Brown, Wht=White |
| 120 vac |
Line - |
Twist together Brown and Brown/White |
| . |
Line - |
Twist together Black and Black/White |
| . |
. |
Do not use Orange. Heat shrink the tip. |
| - |
| 240 vac |
Line - |
Brown/White |
| . |
Line - |
Black |
| . |
. |
Twist together Black/White and Brown |
| . |
. |
Do not use Orange. Heat shrink the tip |
| - |
| 220 vac |
Line - |
Orange |
| . |
Line - |
Black |
| . |
. |
Twist together Black/White and Brown |
| . |
. |
Do not use Brown/White. Heat shrink the tip |
| - |
| 100 vac |
Line - |
Orange |
| . |
Line - |
Black/White |
| . |
. |
Do not use Brown. Heat shrink the tip |
| . |
. |
Do not use Brown/White. Heat shrink the tip |
| . |
. |
Do not use Black/White. Heat shrink the tip |
TDPT-LDEX primary hookup
Line =The AC Wall connection. Blk=Black, Brn=Brown, Wht=White |
| 120 vac |
Line - |
Twist together Brown and Brown/White |
| . |
Line - |
Twist together Black and Black/White |
| . |
. |
Do not use Orange. Heat shrink the tip. |
| - |
| 240 vac |
Line - |
Brown |
| . |
Line - |
Black/White |
| . |
. |
Twist together Black and Brown/White |
| . |
. |
Do not use Orange. Heat shrink the tip |
| - |
| 220 vac |
Line - |
Orange |
| . |
Line - |
Black/White |
| . |
. |
Twist together Black and Brown/White |
| . |
. |
Do not use Brown. Heat shrink the tip |
| - |
| 100 vac |
Line - |
Orange |
| . |
Line - |
Black |
| . |
. |
Do not use Brown. Heat shrink the tip |
| . |
. |
Do not use Brown/White. Heat shrink the tip |
| . |
. |
Do not use Black/White. Heat shrink the tip |
Mojo 779 primary hookup
Line = The AC Wall connection. Blk=Black, Wht=White, Yel=Yellow |
| 120 vac |
Line - |
Twist together Black and Black/Yellow |
| . |
Line - |
Twist together Black/White and Black/Red |
| . |
. |
Do not use White. Heat shrink the tip. |
| - |
| 240 vac |
Line - |
Black |
| . |
Line - |
Black/Red |
| . |
. |
Twist together Black/White and Black/yellow |
| . |
. |
Do not use White. Heat shrink the tip |
| - |
| 220 vac |
Line - |
White |
| . |
Line - |
Black/Red |
| . |
. |
Twist together Black/White and Black/yellow |
| . |
. |
Do not use Black. Heat shrink the tip |
| - |
| 100 vac |
Line - |
White |
| . |
Line - |
Black/White |
| . |
. |
Do not use Black. Heat shrink the tip |
| . |
. |
Do not use Black/Yellow. Heat shrink the tip |
| . |
. |
Do not use Black/Red. Heat shrink the tip |
Mojo 779 Version 3 primary hookup
Line = The AC Wall connection. Blk=Black, Wht=White, Yel=Yellow |
| 120 vac |
Line - |
Twist together Black/Yellow and Black |
| . |
Line - |
Twist together Black/Red and Black/White |
| . |
. |
Do not use White. Heat shrink the tip. |
| - |
| 240 vac |
Line - |
Black/Yellow |
| . |
Line - |
Black/White |
| . |
. |
Twist together Black/Red and Black |
| . |
. |
Do not use White. Heat shrink the tip |
| - |
| 220 vac |
Line - |
White |
| . |
Line - |
Black/Yellow |
| . |
. |
Twist together Black/Red and Black |
| . |
. |
Do not use Black/White, Heat shrink the tip |
| - |
| 100 vac |
Line - |
White |
| . |
Line - |
Black |
| . |
. |
Do not use Black/Yellow. Heat shrink the tip |
| . |
. |
Do not use Black/Red. Heat shrink the tip |
| . |
. |
Do not use Black/White. Heat shrink the tip |
|
Fender Style Power Transformer spec's.
|
|
PART# |
Pri |
MOUNTING in. |
HEIGHT in. |
LENGTH in. |
WIDTH in. |
WATTS |
Ht-ma |
6.3v Amps |
5v Amps |
LBS. |
|
Mojo 779 |
Multi |
3 1/8" |
2 1/4" |
2 3/4" |
2 1/8" |
? |
? |
6.3 / ? |
none |
1.8 LB |
|
125P1B |
120v |
2 1/2 X 2" |
3
1/4" |
3" |
2
1/2" |
6-18 |
70ma |
6.3V / 2A |
2A |
3.5 LB |
|
TDPT-LDEX |
Multi |
2
13/16 x
2 5/16" |
3 1/4" |
3 3/8" |
2 13/16" |
12+ |
125ma |
6.3V / 2A |
2A |
4
LB |
|
041316 |
120v |
2 13/16 X
2 1/4" |
3 7/8" |
3 3/8" |
2 3/4" |
25 |
120ma |
6.3V / 3A |
3A |
5.2 LB |
|
TBPT |
120v |
3 7/16 X
2 3/4" |
4" |
4 1/8" |
3 3/8" |
40+ |
200ma |
6.3V / 6A |
3A |
7.7 LB |
|
022798 |
120v |
3 7/16 X
2 3/4" |
3 3/4" |
4 1/8" |
3 7/16" |
40+ |
140ma |
6.3V / 4A |
3A |
7.7 LB |
|
022756 |
120v |
3
3/4 X 3" |
3 7/8" |
4
1/2" |
3
3/4" |
100 |
310ma |
6.3V / 6A |
none |
8.5 LB |
|